The Power Factor Correction of electrical loads is a problem common to all industrial and commercial users. Every user which utilizes electrical power to obtain work in various forms continuously asks the mains to supply a certain quantity of active power together with reactive power. Most loads on an electrical distribution system can be placed in one of three categories.

• Resistive • Inductive • Capacitive

The most common of these on modern systems is the inductive load. Typical examples includes transformer, fluorescent lighting, AC induction motors, Arc/induction, furnaces etc. which draw not, only active power (KW) from the supply, but also inductive reactive power (KVAr). Common characteristics of these inductive loads is that they utilize a winding to produce an electromagnetic field which allows the motor or transformer to function and requires certain amount of electrical power in order to maintain the field. Therefore Active Power (KW) actually performs the work whereas Reactive Power (KVAr) sustains the electro-magnetic field. This reactive power though is necessary for the equipment to operate correctly but could be interpreted as an undesirable burden on the power supply /Distribution companies. They in turn offer benefits or incentive to consumers to maintain higher power factor near to unity. Most industrial and commercial users are billed in KVAH units therefore higher the power factor lower the KVAH units and KVA demand thereby bringing in direct savings to consumers maintaining higher power factor. Some distribution companies offer discount on KWH billing depending on power factor values. Both way round customer benefits

Why is it important to control Power Factor using right method?
Many consumers are not aware that Power Factor Correction system if not designed as per load characteristics, can itself result and become a cause for major operational problem in the network. Some of the issues can be :

    • Enhanced harmonic distortion.
    • Increased losses due to over or under compensation because of mismatch in load variation and response time of Power Factor Correction System.
    • Increased switching transients due to more no. of steps switched through Contactors.
    • Operational problems in capacitor bank and other network loads due to harmonic resonance.
    • Lot of power quality issues in network becomes visible after installation of inadequate PFC System.
      The above issues may not directly suggest that PF system is responsible but the fact of the matter is that wrongly designed Power Factor Correction system is one of the major cause of operational problems in electrical network.
      With experience of last more than 20 years and with installation base of more than 20000 systems all over India and abroad offer their expertise in designing, supplying and installation of high quality Intelligent Power Factor Correction and Harmonic Filtration systems. These systems are designed on the basis of Power Quality Studies and analysis using advanced simulation tools. Further information is also collected from customer or project consultant. Some of these are :
    • Characteristics and switching time / variation frequency of major loads in the network along with the Rating of Main Transformer and major load feeders where compensation is possible.
    • Identifying balanced and unbalanced load condition in network.
    • Type and amplitude of harmonic distortion with individual harmonic content.http://www.powerqualityindia.com/power-factor-correction-background/
Advertisements

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s